29.03.2013 Views

catalogue 3 1 0 explosionprotectedpro ducts

catalogue 3 1 0 explosionprotectedpro ducts

catalogue 3 1 0 explosionprotectedpro ducts

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

862<br />

ap.280<br />

ap.<br />

46<br />

M25<br />

ap.340<br />

Ceiling cut-out<br />

810+6<br />

315+3<br />

Thickness of<br />

the ceiling<br />

max. 90<br />

min.25<br />

eLLB 20018/18<br />

M8,15 deep<br />

400<br />

M6<br />

approx.<br />

115<br />

approx.<br />

120<br />

ap.<br />

30°<br />

approx.<br />

85<br />

802<br />

ZONE 1 ZONE 2 ZONE 21 ZONE 22<br />

E X - F L U O R E S C E N T L I G H T F I T T I N G S<br />

Technical data<br />

eLLB 20018/18<br />

EX-RECESSED CEILING LIGHT FITTINGS<br />

I eLLB 20018/18 I<br />

Marking to 94/9/EC II 2 G ⎮ II 2 D T80 °C<br />

2 x 18 W<br />

Type of protection EEx ed IIC T4 ⎮ EEx ed ib IIC T4 (CG-variant)<br />

EC-Type Examination Certificate DMT 02 ATEX E 069<br />

Enclosure material painted steel sheet, white optional polished stainles steel<br />

Cover disc single-safety glass pane of 6 mm thick<br />

Ceiling thickness min. 25 mm to max. 90 min.<br />

Rated voltage AC: 110-254 V ± 10 %, 47-63 Hz ⎮ DC: 110-230 V ± 10 %<br />

Rated voltage CG-variant AC: 220-254 V ± 10 %, 47-63 Hz ⎮ DC: 220 V + 25 % – 20 %<br />

Circuit EVG resp. EVG/CG<br />

Rated current 0.18 A resp. 0.19 A (CG-variant)<br />

Power factor cos ϕ ≥ 0.95<br />

Degree of protection to EN 60529 IP 66<br />

Protection class I<br />

Permissible ambient temperature – 20 °C to + 50 °C<br />

Cable entries 2 x EEx e-cable entries M25 x 1.5 (plastic)<br />

for cables from Ø 8 - 17 mm ⎮ 1 x EEx e blanking plug<br />

2 x threaded plugs M25 x 1.5<br />

Connecting terminals L1, L2, L3, L, N, PE; max. 2 x 6 mm 2 single wire per terminal<br />

Lamps Bi-pin lamp: 18 W, socket G13, see accessories<br />

Weight approx. 15 kg ⎮ approx. 16.9 kg (CG-variant)<br />

Ordering details<br />

Type Terminals Through wiring Order No.<br />

double-ended<br />

eLLB 20018/18 (2 x 18 W)<br />

2/6-2 2 x 6 x 1 2190 218 001<br />

2/6-2M1) 2 x 6 x 1 2190 218 101<br />

eLLB 20018/18 CG2) (2 x 18 W)<br />

2/6-2 2 x 6 x 1 2190 218 003<br />

2/6-2M1) 2 x 6 x 1 2190 218 103<br />

Optional: polished stainless steel design<br />

1) M: with 4 metal threads, without cable entries<br />

2) Design single monitored emergency light fitting for use in CEAG Emergency light supply unit<br />

Scope of delivery without lamp and fixing accessories.<br />

See fixing materials and accessories for light fittings on page 2.42.<br />

Dimensions in mm CEAG SICHERHEITSTECHNIK GMBH 2.23<br />

2.23<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!