Q1<br />

F1<br />

Q1<br />

F1<br />

Q1<br />

F1<br />

L1L2L3 N PE<br />

K1<br />

F1.1<br />

1 3 5<br />

2 4 6<br />

1 2 3<br />

Direct on-line starter<br />

g<br />

K1 1 3 5 K2 1 3 5<br />

2 4 6 2 4 6<br />

F1.1<br />

L1L2L3 N PE 1 2 3<br />

Reversing starter<br />

F2<br />

95 F1.1<br />

96 98<br />

0<br />

13<br />

I K1<br />

14<br />

K1<br />

F2<br />

95 F1.1<br />

96 98<br />

0<br />

II<br />

I<br />

K2 21<br />

22<br />

13<br />

K1<br />

14<br />

K1<br />

K1 21<br />

22<br />

13<br />

K2<br />

14<br />

F2<br />

95 F1.1<br />

96 98<br />

K1 1 3 5 K3 1 3 5 0<br />

2 4 6<br />

2 4 6<br />

K1 1 3 5<br />

2 4 6<br />

23<br />

I K2<br />

24<br />

15<br />

13<br />

K2<br />

16 18 14<br />

13<br />

K1<br />

14<br />

K3<br />

K1<br />

21<br />

K1<br />

22<br />

K3<br />

21<br />

13<br />

K3<br />

14<br />

22<br />

K3<br />

K2 K4<br />

31<br />

F1.1 K4<br />

32<br />

L1L2L3 N PE U V W Z X Y<br />

Star-delta starter<br />

K2<br />

ZONE 1 ZONE 2 ZONE 21 ZONE 22<br />

E X - C O N T R O L A N D D I S T R I B U T I O N S S Y S T E M S<br />

Technical data<br />

Light-alloy motor starter<br />

Marking to 94/9/EG II 2 G<br />

Type of protection EEx d IIB T6<br />

EX-DISTRIBUTION SYSTEMS IIB<br />

I Light-alloy motor starter I<br />

EC-type examination certificate LOM 03 ATEX 2004X<br />

Rated voltage 690 V<br />

Rated current 63 A<br />

Protection category IP 65<br />

Terminal cross-section up to 240 mm 2<br />

Weight see ordering details<br />

Ordering details type: direct on-line starter<br />

Motorstarter<br />

Motor capacity Main switch Cable entry Weight Order No.<br />

AC-3 to 400 V<br />

4.0 KW 25 A 2 x M25 4.0 kg EXKO 732 101 M<br />

4.0 KW 25 A 2 x M25 12.0 kg EXKO 732 102 M<br />

5.5 KW 40 A 2 x M25 12.0 kg EXKO 732 103 M<br />

8.0 KW 40 A 2 x M25 16.8 kg EXKO 732 104 M<br />

12.5 KW 63 A 2 x M32 17.2 kg EXKO 732 105 M<br />

15.0 KW 63 A 2 x M32 18.8 kg EXKO 732 106 M<br />

Ordering details type: reversing starter<br />

Motor capacity Main switch Cable Weight Order No.<br />

Dimensions in mm CEAG SICHERHEITSTECHNIK GMBH 8.49<br />

entry<br />

4.0 KW 25 A 2 x M25 4.0 kg EXKO 732 107 M<br />

4.0 KW 25 A 2 x M25 12.0 kg EXKO 732 108 M<br />

5.5 KW 40 A 2 x M25 12.0 kg EXKO 732 109 M<br />

8.0 KW 40 A 2 x M25 16.8 kg EXKO 732 110 M<br />

12.5 KW 63 A 2 x M32 17.2 kg EXKO 732 111 M<br />

15.0 KW 63 A 2 x M32 18.8 kg EXKO 732 112 M<br />

Ordering details type: star delta starter<br />

Motor capacity Main switch Cable Weight Order No.<br />

entry<br />

12.5 KW 40 A 2 x M25 17.2 kg EXKO 732 113 M<br />

18.5 KW 40 A 2 x M32 19.7 kg EXKO 732 114 M<br />

25 KW 40 A 2 x M32 25.3 kg EXKO 732 115 M<br />

Further switching capacities on request.<br />