MSHA PROGRAM POLICY MANUAL <strong>VOLUME</strong> V<br />
of 40 volts or less), provided such equipment is not<br />
required to be permissible; <strong>and</strong><br />
12. installation, repair, <strong>and</strong> guarding of trolley wires <strong>and</strong><br />
trolley feeder wires.<br />
Section 75.510 states that energized trolley wires may be<br />
repaired only by a person trained to perform electrical work <strong>and</strong><br />
to maintain electrical equipment. Repair work is not required to<br />
be performed by a qualified person but must be performed by a<br />
person trained to repair <strong>and</strong> maintain energized trolley wires.<br />
However, electrical work, such as connecting a feeder wire inside<br />
the enclosed housing of a rectifier, is required to be performed<br />
by a qualified person or by a person trained to perform<br />
electrical work <strong>and</strong> to maintain electrical equipment under the<br />
direct supervision of a qualified person.<br />
The phrase "under the direct supervision of a qualified person"<br />
must, as a minimum, include the following:<br />
1. The qualified person shall examine <strong>and</strong>/or test an<br />
electric circuit or machine <strong>and</strong> determine the need for<br />
repair or maintenance;<br />
2. The qualified person must give specific instructions to<br />
the employee assigned to perform this work with respect<br />
to the nature <strong>and</strong> extent of the repairs to be performed<br />
<strong>and</strong>, where necessary, prescribe the manner in which the<br />
work is to be performed;<br />
3. The qualified person is, at all times, under continuing<br />
duty to instruct, advise, or consult with the employee in<br />
the event the work which he has assigned cannot be<br />
performed by the employee in the manner prescribed; <strong>and</strong><br />
4. The qualified person must examine <strong>and</strong> test, if necessary,<br />
the completed work before the circuit is energized or the<br />
machine is returned to service.<br />
When a cable splice is made by a person other than a qualified<br />
person, the splice shall be inspected by a qualified person prior<br />
to reinsulation of the power conductors <strong>and</strong> prior to <strong>and</strong> after<br />
the final outer jacket is applied.<br />
Testing <strong>and</strong> troubleshooting of energized equipment shall be done<br />
only by qualified persons, except that a person trained to<br />
February 2003 (Release V-33) 58