MSHA PROGRAM POLICY MANUAL <strong>VOLUME</strong> V<br />

<strong>Mine</strong>s using single-phase power originating at the power company's<br />

secondary <strong>and</strong> extending underground cannot normally comply with<br />

this Section due to the power company's practice of connecting<br />

the lightning arrester ground to the grounded neutral which also<br />

connects to the center tap of the transformer, unless an<br />

isolation transformer is installed or the power company isolates<br />

the lightning arrester ground from the center tap ground <strong>and</strong> a<br />

separate neutral ground field is established.<br />

75.523-1 Deenergization of Self-Propelled Electric Face<br />

Equipment Installation Requirements<br />

A machine that can only be operated from a remote location is not<br />

required to be provided with a device that will quickly<br />

deenergize the tramming motors of the machine in the event of an<br />

emergency. However, if at any time the remote controls are<br />

placed on the machine for the purpose of tramming the machine, or<br />

if for any other reason the operator trams the machine from<br />

onboard or alongside the machine, the machine shall be provided<br />

with a device that meets the requirements of this Section <strong>and</strong><br />

Section 75.523-2.<br />

Any device other than a bar or lever used for deenergizing<br />

tramming motors such as a "dead man control" can be accepted only<br />

by an approval letter from Technical Support.<br />

75.523-2 Deenergization of Self-Propelled Electric Face<br />

Equipment; Performance Requirements<br />

The actuating bar or lever <strong>and</strong> its associated linkage should be<br />

designed to activate a circuit breaker, control switch, hydraulic<br />

valve, or other device that will deenergize the tramming motors<br />

when the actuating bar or lever is depressed.<br />

The bar or lever shall extend a sufficient distance in each<br />

direction to provide a ready means of deenergizing the tramming<br />

motors without requiring the operator to change position or<br />

search for a safe stop switch if an emergency occurs.<br />

The actuating bar or lever shall be designed so that a horizontal<br />

or vertical (downward) pressure of 15 pounds force shall cause<br />

deenergization of the tramming motors before the bar has traveled<br />

more than 2 inches.<br />

February 2003 (Release V-33) 68