Page 922 of 1536 Chapter 6 — 2 <strong>Mb</strong> <strong>PRI</strong> Implementation<br />

1 Add a <strong>PRI</strong> loop. Use Overlay 17.<br />

Prompt Response Description<br />

REQ CHG<br />

2 Add a DCHI or DDCH. Use Overlay 17.<br />

553-3011-315 St<strong>and</strong>ard 10.0 May 1999<br />

TYPE CFN configuration data block<br />

CEQU YES changes to common equipment<br />

<strong>PRI</strong>2 XXX where XXX is the <strong>DTI</strong>/<strong>PRI</strong> digital card number<br />

(1-9)<br />

MODE PRA select Primary Rate Interface mode<br />

Prompt Response Description<br />

REQ CHG<br />

TYPE CFN Configuration data block<br />

ADAN NEW DCH<br />

1-15<br />

CHG DCH<br />

1-15<br />

Out DCH<br />

1-15<br />

Add a primary D-Channel port number. Any<br />

unused SDI port number<br />

Change a primary D-Channel<br />

Out the primary D-Channel<br />

CTYP DCHI/MSDL DCHI for existing D-Channel configuration.<br />

(NTAK93 D-channel)<br />

MSDL for Downloadable D-Channel configuration<br />

(NTBK51 D-channel). The MSDL base<br />

<strong>and</strong> D-Channel application software will be<br />

downloadable into the DDCH card.<br />

CDNO 1-9 Card slot number to be used as the primary<br />

DDCH/DCHI<br />

PORT 1 PORT must be set to "1"<br />

DES Back-up DCHI port number, if required<br />

DPNS NO Default is no<br />

USR <strong>PRI</strong> <strong>PRI</strong>: D-channel is for ISDN <strong>PRI</strong> only