Chapter 13 — ISDN Feature Implementation Page 1181 of 1536<br />

LD 73 – Define the alarm h<strong>and</strong>ler in the firmware, disable or enable the grade<br />

of service processing in the software, <strong>and</strong> define the number of seconds<br />

before the firmware sends an ERR message.<br />

Prompt Response Description<br />

REQ NEW, CHG New, or change.<br />

TYPE <strong>PRI</strong>2 <strong>2.0</strong> <strong>Mb</strong>it Primary Rate Interface data block.<br />

...<br />

ALRM REG<br />

...<br />

NOOS<br />

...<br />

ALT<br />

(NO)<br />

YES<br />

Regular firmware alarm h<strong>and</strong>ler (RAI transmission is<br />

controlled by software).<br />

Alternate firmware alarm h<strong>and</strong>ler (Immediate transmission<br />

of RAI by firmware).<br />

Grade of service feat.<br />

Enables current grade of service feat.<br />

Alternate grade of service feat.<br />

RATS 1-(10)-15 The number of consecutive seconds the firmware has to<br />

check <strong>and</strong> validate error rate condition.<br />

Option 11C <strong>2.0</strong> <strong>Mb</strong> <strong>DTI</strong>/<strong>PRI</strong> <strong>Administration</strong> <strong>and</strong> <strong>Maintenance</strong> guide