Page 1192 of 1536 Chapter 13 — ISDN Feature Implementation<br />

Japan D70, non-Asia Pacific connectivity<br />

LD 17 – Define the ISDN <strong>PRI</strong> to D70 connectivity.<br />

Prompt Response Description<br />

REQ CHG Change.<br />

TYPE CFN Configuration record.<br />

- ADAN CHG DCH x Change a D-channel on logical port 0-15 (all other machine<br />

types).<br />

... ... ...<br />

- IFC D70 Interface type for Japan D70 connectivity.<br />

- CNEG (1) 2 The required channel negotiation option, either exclusive<br />

(the default) or preferred.<br />

LD 16 – Define the ISDN <strong>PRI</strong> to D70 connectivity.<br />

Prompt Response Description<br />

REQ NEW, CHG New, or change.<br />

TYPE RDB Route Data Block.<br />

CUST xx Customer number.<br />

ROUT xxx Route number.<br />

... ... ...<br />

IFC D70 Interface type for Japan D70 connectivity.<br />