Page 1302 of 1536 Chapter 13 — ISDN Feature Implementation<br />

Japan D70 nB+D<br />

LD 17 – Configure nB+D for D70.<br />

Prompt Response Description<br />

REQ CHG Change.<br />

TYPE CFN Configuration Record.<br />

ADAN NEW DCH 0-15 Add a primary D-channel on logical port.<br />

CTYP aaaa Card type.<br />

USR <strong>PRI</strong> D-channel mode.<br />

IFC D70 Interface type for Japan D70.<br />

DCHL 1-9 1-126 <strong>PRI</strong> loop number <strong>and</strong> interface identifier for the DCHI when<br />

IFC =D70.<br />

...<br />

OTBF 1-(32)-127 Number of output request buffers.<br />

<strong>PRI</strong> 1-9 1-126<br />

<br />

DRAT (56K), 64KC, 64KI D-channel transmission.<br />

...<br />

553-3011-315 St<strong>and</strong>ard 10.0 May 1999<br />

Loop number <strong>and</strong> interface ID. Note that the interface ID<br />

range is larger when IFC=D70.<br />

End definition of <strong>PRI</strong> loops.<br />

ADAN NEW BDCH 1-15 Add a primary D-channel on logical port.<br />

PDCH 0 -15 Primary D-channel.<br />

CTYP MSDL Card type, where MSDL = Downloadable D-Channel<br />

Daughterboard.<br />

BCHL 1-9 1-126 <strong>PRI</strong> loop number <strong>and</strong> interface identifier for the DCHI when<br />

IFC=D70.<br />

...