Page 1200 of 1536 Chapter 13 — ISDN Feature Implementation<br />

0-1 Port number of the NTBK51AA, if the NTBK51AA is<br />

used for D-Channel h<strong>and</strong>ling on large systems<br />

(Options 51C, 61C, 81, 81C).<br />

Port 0 of the NTBK51AA can only be defined to work<br />

with Loop 0 of the NT5D97AA DDP2 card, <strong>and</strong> Port 1<br />

of the NTBK51AA can only be defined to work with<br />

Loop 1 of the NT5D97AA. This relationship must be<br />

reflected in the BCHL prompt, which follows later<br />

(either 0 or 1 must be entered when specifying the loop<br />

number used by the Backup D-Channel).<br />

553-3011-315 St<strong>and</strong>ard 10.0 May 1999<br />

1 Port number of the NTBK51BA, for Option 11C.<br />

- RCVP YES Auto-recovery to primary D-Channel.<br />

...<br />

1-9 <strong>PRI</strong>/<strong>PRI</strong>2 loop number for D-channel (Option 11C).<br />

- USR <strong>PRI</strong> This D-Channel is used for Primary Rate only.<br />

- IFC APAC Asia Pacific ISDN interface.<br />

- - CNTY HKNG Hong Kong<br />

...<br />

PROG<br />

NCHG<br />

MALE<br />

MCON<br />

Progress signal.<br />

NCHG = No Change. This is the default for all Asia<br />

Pacific interfaces except Australia (<strong>and</strong> Japan <strong>and</strong><br />

Singapore, which do not support the Progress signal<br />

for <strong>PRI</strong>).<br />

MALE = Alert message.<br />

MCON = Connect message. This is the default for the<br />

Australia interface.<br />

Note: The PROG prompt should not be configured for<br />

Japan <strong>and</strong> Singapore, since these countries do not<br />

support the Progress signal.<br />

- RCVP YES Auto-recovery to primary D-Channel.<br />

- BCHL 0-159 <strong>PRI</strong>2 loop number for the Back-up D-channel, for large<br />

systems (Options 51C-81/81C).<br />

If the NTBK51AA is used for D-Channel h<strong>and</strong>ling, only<br />

loop 0 or 1 can be configured.