Page 1294 of 1536 Chapter 13 — ISDN Feature Implementation<br />

Establish data interface process at the ISPC SLAVE side of an ISPC link at<br />

loop (l) <strong>and</strong> channel (ch), where “N” = the “number of tries” counter. The<br />

actual range of N = 0-(1)-255.<br />

When N = 0, the mode is set to AUTOMATIC. This mode requires one TDS<br />

slot <strong>and</strong> one DTR unit. This mode is not recommended for use on small<br />

systems or systems loaded with heavy traffic.<br />

When N > 0, the process is activated for a period of up to N * 30 minutes.<br />

The available range goes from 30 minutes (N = 1) to 128.5 hours or 5 days<br />

(N = 255).<br />

If no value is entered for N, it defaults to a value of 1. When N = 1, one<br />

attempt will be made to establish the data interface process before the<br />

ISPC slave D-channel is released.<br />

RLS ISPC l ch Stop the data interface establishment process.<br />

When this comm<strong>and</strong> is entered, the mode becomes MANUAL <strong>and</strong> the<br />

number of attempts to be performed = 0.<br />

553-3011-315 St<strong>and</strong>ard 10.0 May 1999