<strong>In</strong> <strong>Situ</strong> <strong>Flushing</strong> Project Summaries<br />

GWRTAC Case Study Database<br />

applied in four increments, and since the holes percolated at different rates, the time interval<br />

between doses varied from hole to hole. Testing in three pits was stopped when time intervals<br />

between surfactant applications approached ten hours, creating unacceptable permeabilities were<br />

being created. After seven days of washing the pits received rinses of local, potable well water.<br />

Undisturbed soils beneath each hole were analyzed for residual contamination after nine to 14 PV<br />

of surfactant solution had been applied, and after the final potable water rinses. Contaminant<br />

concentrations in these soils were 5,000 to 10,000 ug/g, which was comparable to prewash<br />

conditions. Researchers concluded that the in situ soil washing was not measurably effective, and<br />

that it is likely that the same ineffectiveness would occur at other chronic spill sites with<br />

contaminants with high soil-sorption values (K>103).<br />

Project costs were not available from reference source.<br />

<strong>Report</strong>(s)/Publication(s) (Additional <strong>In</strong>formation Sources):<br />

Nash, J. H., 1988, Project Summary Field Studies of <strong>In</strong> <strong>Situ</strong> Soil Washing, EPA/600/S2-87/110,<br />

U.S. Environmental Protection Agency, February 1988.<br />

U.S. Environmental Protection Agency, 1991: Engineering Bulletin <strong>In</strong> <strong>Situ</strong> Soil <strong>Flushing</strong>,<br />

EPA/540/2-91/021, U.S. EPA Office of Emergency and Remedial Response (OERR), Washington,<br />

DC 20460, Office of Research and Development (ORD), Cincinnati, Ohio 45268, 8 pp., October<br />

1991.<br />

Ground-Water Remediation Technologies Analysis Center<br />

Operated by Concurrent Technologies Corporation<br />

Appendix - Page 100 of 164<br />

Copyright GWRTAC 1998<br />

Revision 1<br />

Tuesday, November 17, 1998

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!