<strong>In</strong> <strong>Situ</strong> <strong>Flushing</strong> Project Summaries<br />

GWRTAC Case Study Database<br />

GWRTAC ID: FLSH0004<br />

Project Name: Chem-Dyne, Hamilton, OH<br />

City: Hamilton State/Province: OH<br />

Primary GWRTAC Personal<br />

Communication Source<br />

(Name/Organization):<br />

Project Summary:<br />

Larry Schmidt<br />

U.S. EPA<br />

<strong>Report</strong>(s)/Publication(s) (GWRTAC Source):<br />

<strong>In</strong>ternet URL http://www.epa.gov/superfund/index.htm.<br />

The following text is from notes taken from May 1997 conversation with EPA RPM:<br />

The 20-acre site is located adjacent to the Great Miami River. The constituent plume was present<br />

in an alluvial water table aquifer; the depth of the water table is approximately 20 to 30 feet below<br />

the ground surface (bgs). The valley floor, at 200 feet bgs, formed the confining layer, however the<br />

contaminants were present at 80 feet bgs and shallower. No physical containment, such as a<br />

slurry wall, was constructed at the site. A total of 25 shallow (30 feet bgs) and deep (80 feet bgs)<br />

wells were utilized for groundwater extraction. Re-injection of the treated groundwater was<br />

accomplished through approximately eight shallow (20 feet bgs) wells. A total of 859 gpm<br />

groundwater is pumped and treated. Some treated groundwater is re-injected, while a percentage<br />

is discharged via an NPDES permit. Re-injection was discontinued due to the high cost of filtering<br />

groundwater prior to re-injection.<br />

Results and cost information were not available from GWRTAC source.<br />

<strong>Report</strong>(s)/Publication(s) (Additional <strong>In</strong>formation Sources):<br />

<strong>In</strong>ternet URL http://www.epa.gov/superfund/index.htm.<br />

Ground-Water Remediation Technologies Analysis Center<br />

Operated by Concurrent Technologies Corporation<br />

Appendix - Page 7 of 164<br />

Copyright GWRTAC 1998<br />

Revision 1<br />

Tuesday, November 17, 1998

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!