26.10.2012 Views

Statement List (STL) - DCE FEL ČVUT v Praze

Statement List (STL) - DCE FEL ČVUT v Praze

Statement List (STL) - DCE FEL ČVUT v Praze

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

English<br />

Mnemonics<br />

German<br />

Mnemonics<br />

Program<br />

Elements<br />

Catalog<br />

Description<br />

FR FR Timers Enable Timer (Free)<br />

INC INC Accumulator Increment ACCU 1-L-L<br />

Overview of All <strong>STL</strong> Instructions<br />

INVD INVD Convert Ones Complement Double Integer (32-Bit)<br />

INVI INVI Convert Ones Complement Integer (16-Bit)<br />

ITB ITB Convert Integer (16-Bit) to BCD<br />

ITD ITD Convert Integer (16-Bit) to Double Integer (32-Bit)<br />

JBI SPBI Jumps Jump if BR = 1<br />

JC SPB Jumps Jump if RLO = 1<br />

JCB SPBB Jumps Jump if RLO = 1 with BR<br />

JCN SPBN Jumps Jump if RLO = 0<br />

JL SPL Jumps Jump to Labels<br />

JM SPM Jumps Jump if Minus<br />

JMZ SPMZ Jumps Jump if Minus or Zero<br />

JN SPN Jumps Jump if Not Zero<br />

JNB SPBNB Jumps Jump if RLO = 0 with BR<br />

JNBI SPBIN Jumps Jump if BR = 0<br />

JO SPO Jumps Jump if OV = 1<br />

JOS SPS Jumps Jump if OS = 1<br />

JP SPP Jumps Jump if Plus<br />

JPZ SPPZ Jumps Jump if Plus or Zero<br />

JU SPA Jumps Jump Unconditional<br />

JUO SPU Jumps Jump if Unordered<br />

JZ SPZ Jumps Jump if Zero<br />

L L Load/Transfer Load<br />

L DBLG L DBLG Load/Transfer Load Length of Shared DB in ACCU 1<br />

L DBNO L DBNO Load/Transfer Load Number of Shared DB in ACCU 1<br />

L DILG L DILG Load/Transfer Load Length of Instance DB in ACCU 1<br />

L DINO L DINO Load/Transfer Load Number of Instance DB in ACCU 1<br />

L STW L STW Load/Transfer Load Status Word into ACCU 1<br />

L L Timers Load Current Timer Value into ACCU 1 as Integer (the<br />

current timer value can be a number from 0 to 255, for<br />

example, L T 32)<br />

L L Counters Load Current Counter Value into ACCU 1 (the current<br />

counter value can be a number from 0 to 255, for<br />

example, L C 15)<br />

LAR1 LAR1<br />

Load/Transfer Load Address Register 1 from ACCU 1<br />

LAR1 LAR1 Load/Transfer Load Address Register 1 with Double Integer (32-Bit<br />

Pointer)<br />

LAR1 AR2 LAR1 AR2 Load/Transfer Load Address Register 1 from Address Register 2<br />

LAR2<br />

LAR2<br />

Load/Transfer Load Address Register 2 from ACCU 1<br />

LAR2 LAR2 Load/Transfer Load Address Register 2 with Double Integer (32-Bit<br />

Pointer)<br />

<strong>Statement</strong> <strong>List</strong> (<strong>STL</strong>) for S7-300 and S7-400 Programming<br />

A5E00706960-01 A-9