03.05.2014 Views

SG4E Full Rev01.pdf - Datasensor

SG4E Full Rev01.pdf - Datasensor

SG4E Full Rev01.pdf - Datasensor

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

SG4-E INSTRUCTION MANUAL<br />

Example 4: Milling machines<br />

A milling machine is a machine tool used for<br />

the shaping of metals and other solid<br />

materials. Operator hands and body must be<br />

protected from being dragged, entangled or<br />

cut by the tool / spindle.<br />

Solution: SG4-E series safety light curtain is<br />

the best solution considering the required<br />

safety levels and application type. When<br />

even just one of the light curtain beams is<br />

interrupted, the machine is immediately stopped.<br />

Benefits: Highly reduced profile size guarantees installation flexibility for machine<br />

dimensions.<br />

The rotating brackets, available as accessories, ease installation.<br />

1.5 SAFETY INFORMATIONS<br />

For a correct and safe use of the safety light curtains of the SG4<br />

series, the following points must be observed:<br />

The stopping system of the machine must be electrically controlled<br />

This control system must be able to stop the dangerous movement of the machine<br />

within the total machine stopping time T as reported in par. 1.3.3 and during all<br />

working cycle phases<br />

Mounting and connection of the safety light curtain must be carried out by qualified<br />

personnel only, according to the indications included in the special sections (see<br />

chapters 2, 3, 4, 5) and in the applicable standards<br />

The safety light curtain must be securely placed in a particular position so that access<br />

to the dangerous zone is not possible without the interruption of the beams (see<br />

chapters 2, 3)<br />

The personnel operating in the dangerous area must be well trained and must have<br />

adequate knowledge of all the operating procedures of the safety light curtain<br />

The TEST button must be located outside the protected area because the operator<br />

must check the protected area during all Test and Reset operations<br />

Please carefully read the instructions for the correct functioning before powering the light<br />

curtain.<br />