INSTALLATION<br />

2<br />

ESPE has to be correctly aligned, press slightly on the product side in both directions<br />

the red LED must not turn on<br />

The activation of the TEST function (on TX side) causes the opening of the OSSD<br />

outputs (red LED, OSSD on RX side, ON and controlled machine stop)<br />

The response time at machine STOP, including the ESPE and machine response<br />

times, must be included in the limits defined in the calculation of the safety distance<br />

(refer to chapter 2)<br />

The safety distance between the dangerous parts and ESPE must comply with the<br />

requirements indicated in chapter 2<br />

A person must not access or remain between ESPE and the dangerous parts of the<br />

machine<br />

Access to the dangerous areas of the machine must not be possible from any<br />

unprotected area<br />

ESPE must not be disturbed by external light sources, ensuring that it remains in<br />

NORMAL OPERATION condition for at least 10-15 minutes and, placing the specific<br />

test piece in the protected area, in the SAFE state for the same period<br />

Verify the correspondence of all the accessory functions, activating them in the<br />

different operating conditions<br />