SG4E Full Rev01.pdf - Datasensor
SG4E Full Rev01.pdf - Datasensor
SG4E Full Rev01.pdf - Datasensor
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FUNCTIONS<br />
7<br />
The sensor named A is the farthest from the light curtain, so its beam is intercepted first.<br />
Making reference to the next figure, since the pack goes from right to left only, B sensor can’t<br />
be intercepted first; if this happens the device doesn’t enter muting function.<br />
“V” indicates a constant speed. As a consequence, “d1” is fixed according to the following<br />
formula:<br />
d1[cm] = V[m/s] * T12[s] * 100<br />
Fig. 44 – L muting connection<br />
BCM Configuration: Muting Direction<br />
T (bidirectional)<br />
L (monodirectional)<br />
Led 6 ON Green<br />
Led 6 OFF<br />
ACM Configuration: Muting Direction<br />
43