2<br />

SG4-E INSTRUCTION MANUAL<br />

The minimum distance depends on:<br />

operating distance between emitter (TX) and receiver (RX);<br />

real aperture angle of ESPE (EAA); especially:<br />

for ESPE type 4 EAA = 5° ( = ± 2,5°)<br />

Diagram of Fig. 10 shows the minimum distance from the reflecting surface (Dsr), based on<br />

the operating distance:<br />

ESPE<br />

Type 4<br />

Fig. 10<br />

The formula to get Dsr is the following:<br />

Dsr (m) = 0.15<br />

Dsr (m) = 0.5 x operating distance (m) x tg 2<br />

for operative distances < 3 m<br />

for operative distances 3 m<br />

2.2.2 Distance between homologous devices<br />

If different safety devices have to be installed in adjacent areas, the emitter of one device<br />

must not interfere dangerously with the receiver of the other device.<br />

The TXB interfering device must be positioned outside a minimum Ddo distance from the<br />

TXA – RXA emitter-receiver couple axis.<br />

Fig. 11 – Distance between homologous devices<br />

This minimum Ddo distance depends on:<br />

the operating distance between emitter (TXA) and receiver (RXA)<br />

the effective aperture angle of the ESPE (EAA)<br />