FUNCTIONS<br />

7<br />

BCM Configuration: Override Mode<br />

Level<br />

Edge<br />

Led 8 ON Green<br />

Led 8 OFF<br />

ACM Configuration: Override Mode<br />

7.8.2 Override timeout<br />

BCM mode<br />

In both modes Override status timeout is 120s: if Override conditions remain active and both<br />

Override contacts remain closed (this condition only in Level Trigger Mode) more than 120s,<br />

the Override goes low in any case after a maximum of 120s.<br />

ACM mode<br />

Override timeout is the maximum duration of override. This time can be chosen by the user<br />

from a minimum of 1 minute to a maximum of 256 minutes.<br />

After timeout the override ends even if the conditions for its activation are still existing and<br />

the override inputs are active.<br />

OVERRIDE STATUS is an output signal that informs the user if the override inputs are active<br />

with override conditions present.<br />

Fig. 51 – Override timeout timings<br />