FUNCTIONS<br />
7<br />
BCM Configuration: Override Mode<br />
Level<br />
Edge<br />
Led 8 ON Green<br />
Led 8 OFF<br />
ACM Configuration: Override Mode<br />
7.8.2 Override timeout<br />
BCM mode<br />
In both modes Override status timeout is 120s: if Override conditions remain active and both<br />
Override contacts remain closed (this condition only in Level Trigger Mode) more than 120s,<br />
the Override goes low in any case after a maximum of 120s.<br />
ACM mode<br />
Override timeout is the maximum duration of override. This time can be chosen by the user<br />
from a minimum of 1 minute to a maximum of 256 minutes.<br />
After timeout the override ends even if the conditions for its activation are still existing and<br />
the override inputs are active.<br />
OVERRIDE STATUS is an output signal that informs the user if the override inputs are active<br />
with override conditions present.<br />
Fig. 51 – Override timeout timings<br />