7<br />

SG4-E INSTRUCTION MANUAL<br />

FIXED BLANKING<br />

The panel on the right shows the settings of the active blanking zone (in the example here<br />

below the active blanking zone has a dimension of 3 beams and is 7 beams from the bottom<br />

of the light curtain; no tolerance is set).<br />

FIXED BLANKING WITH INCREASED TOLERANCE (TOP or BOTTOM )<br />

The example below shows a setting with fixed blanking with increased tolerance top: over<br />

this zone fixed blanking zones only are allowed; under this zone fixed and total surveillance<br />

blanking zones are allowed.<br />

FLOATING BLANKING WITH TOTAL SURVEILLANCE<br />

Floating objects can move up or down intercepting different beams while moving; the objects<br />

can’t overlap nor change relative positions.<br />

Object must be always present in the protected area and intercept the configured number of<br />

beams with a mandatory fixed tolerance of one beam; that is necessary since a moving<br />

object will always intercept a different number of beams.<br />

60