DIAGNOSTIC<br />
8<br />
NORMAL<br />
OPERATION<br />
BLANKING<br />
ONLY<br />
NORMAL<br />
OPERATION<br />
MUTING ONLY<br />
FAILURE<br />
INFORMATION<br />
VALID BLANKING<br />
(OSSDS ON)<br />
INVALID BLANKING<br />
(OSSDS OFF)<br />
BCM TOLERANCE<br />
ACTIVE<br />
MUTING ACTIVE<br />
OVERRIDE ACTIVE<br />
OVERRIDE<br />
ATTENTION<br />
STATUS<br />
OVERRIDE TIMINGS<br />
FAILURE<br />
LAMP FAILURE<br />
FAILURE ON<br />
OSSDS<br />
FAILURE ON<br />
MICROPROCESSOR<br />
FAILURE ON<br />
OPTICS<br />
FAILURE ON EDM<br />
FAILURE ON<br />
RESTART<br />
COMUNICATION<br />
FAILURE<br />
BCM<br />
CONFIGURATION<br />
FAILURE<br />
ACM<br />
CONFIGURATION<br />
FAILURE<br />
CRITICAL FAILURE<br />
POWER SUPPLY<br />
FAILURE<br />
blanking zones not<br />
respected<br />
reconfigure blanking (teachin<br />
if BCM)<br />
check effective ESPE<br />
resolution and intentional<br />
activation of tolerance<br />
function<br />
if unexpected OSSD OFF<br />
with muting active, check<br />
partial muting configuration<br />
trigger override button to<br />
force OSSDs ON<br />
check and repeat override<br />
activation sequence<br />
check override connections<br />
check if lamp connections<br />
and/or if lamp is broken<br />
Activate RESET line. If error<br />
persists contact Datalogic<br />
Automation Technical<br />
Support<br />
Activate RESET line. If error<br />
persists contact Datalogic<br />
Automation Technical<br />
Support<br />
Activate RESET line. If error<br />
persists contact Datalogic<br />
Automation Technical<br />
Support<br />
Check EDM feedback line<br />
and EDM configuration.<br />
Activate RESET line<br />
Check RESTART line<br />
connection. Activate RESET<br />
line<br />
Check cascade connection<br />
and correct mounting of<br />
terminator cap. Activate<br />
RESET line<br />
Re-operate Basic<br />
Configuration. If error<br />
persists contact Datalogic<br />
Automation Technical<br />
Support<br />
Re-operate Advanced<br />
Configuration. If error<br />
persists contact Technical<br />
Support<br />
Turn ON/OFF ESPE. If error<br />
persists contact Datalogic<br />
Automation Technical<br />
Support<br />
Check Power Supply<br />
Connection. If error persists<br />
contact Technical Support<br />