7<br />

SG4-E INSTRUCTION MANUAL<br />

7.7.5 Muting timeout<br />

Muting timeout is a time that defines the maximum duration of muting function; after the<br />

timeout the muting ends.<br />

This time can be set from the user in both BCM and ACM mode.<br />

In BCM mode the user can select a timeout of 10 minutes or infinite; “infinite” means that<br />

muting timeout could never end: if the conditions of muting persist, the muting function still<br />

continues to exist. This is not compliant with the 61496-1 rule and the user is warned about<br />

it.<br />

Fig. 45 – Muting timeout<br />

The user can personalize the timeout from 10 minutes to 1080 minutes (that correspond to<br />

18 hours) with steps of 1 minute; the user can even set infinite timeout. In this case there’s a<br />

warning that alerts the user that this timeout is not IEC 61496-1 compliant.<br />

BCM Configuration: Muting Timeout<br />

10 min Led 7 ON Green<br />

infinite<br />

Led 7 OFF<br />

ACM Configuration: Muting Timeout<br />

Note: Infinite is not 61496-1 compliant thus the user is warned about it<br />