FUNCTIONS<br />

7<br />

7.5 EDM SELECTION<br />

This function lets the user to select or exclude the monitoring of the external switching<br />

devices.<br />

BCM Configuration: EDM Selection<br />

Enabled<br />

Disabled<br />

Led 4 ON Yellow<br />

Led 4 OFF<br />

ACM Configuration: EDM Selection<br />

To increase safety level, when EDM is set OFF, at start-up ESPE checks if EDM input is<br />

floating.<br />

7.6 REDUCTION RANGE<br />

This function allows the user to select the maximum operating distance at which the curtains<br />

can be mounted.<br />

When Long Range is selected on RX, if TX is configured as Long Range the maximum<br />

operating distance is 20m (for resolution 30mm) and 7m (for resolution 14mm); if TX is<br />

configured as Short Range the maximum operating distance is 12m (for resolution 30mm)<br />

and 4m (for resolution 14mm).<br />

When Short Range is selected on RX, if TX is configured as Long Range the maximum<br />

operating distance is 6m (for resolution 30mm) and 2m (for resolution 14mm); if TX is<br />

configured as Short Range the maximum operating distance is 4m (for resolution 30mm) and<br />

1m (for resolution 14mm).<br />

The user can select this function for RX side through ACM and for TX side through BCM.<br />

Fig. 38 – Reduction Range<br />