SG4-E INSTRUCTION MANUAL<br />
NORMAL OVERRIDE RESTART<br />
The OSSDs go in normal operation state after the RESTART signal goes low, and not after<br />
500msec. A timeout of 5s on the high RESTART brings the ESPE in failure lockout.<br />
The outputs go high after a time that is the maximum value between the recovery time and<br />
the time of restart high (greater or equal to 500msec), so this time can be any value between<br />
500ms and 5s.<br />
When override ends if the beams are free the ESPE goes to interlock state and a restart is<br />
required to achieve normal operation state.<br />
OVERRIDE STATUS is an output signal that informs the user if the override inputs are active<br />
with override conditions present.<br />
Fig. 54 – Override restart timings (normal)<br />
ACM Configuration: Normal Override Restart Selection<br />