INSTALLATION<br />

2<br />

2.2.3 Emitter and Receiver Orientation<br />

The two units shall be assembled parallel each other, with the beams arranged at right<br />

angles with the emission and receiving surface, and with the connectors pointing to the same<br />

direction.<br />

The configurations shown in Fig. 14 must be avoided:<br />

NO<br />

NO<br />

Fig. 14 – Light curtains orientation<br />

2.2.4 Use of deviating mirrors<br />

The control of any dangerous area, with several but adjacent access sides, is possible using<br />

only one safety device and well-positioned deviating mirrors.<br />

Fig. 15 shows a possible solution to control three different access sides, using two mirrors<br />

placed at 45° with respect to the beams.<br />

Fig. 15 – Use of deviating mirrors<br />

The operator must respect the following precautions when using the deviating mirrors:<br />

The alignment of the emitter and the receiver can be a very critical operation when<br />

deviating mirrors are used. Even very small displacements of the mirror is enough to<br />

lose alignment. The use of Datalogic laser pointer accessory is recommended under<br />

these conditions<br />

The minimum safety distance (S) must be respected for each single section of the<br />

beams.<br />

The effective operating range decreases by about 15% by using only one deviating<br />

mirror, the percentage further decreases by using 2 or more mirrors (for more details<br />

refer to the technical specifications of the mirrors used).<br />