28 Multi-Wave PE653-PE953 Installation Guide<br />

240V 2-Speed pump + any 3 120 VAC auxiliary equipment<br />

Select Breaker to match wire size<br />

and load requirement. Observe<br />

maximum control circuit capacity.<br />

Make sure that voltage selector switch is in 240V<br />

position before applying power to Terminals 1 & 2<br />

NEUTRAL BUS<br />

2-pole Breaker<br />

120V<br />

240V<br />

RECEIVER<br />

POWER<br />

SUPPLY<br />

1 2 3 4 5<br />

1-pole<br />

Breakers<br />

15 A. Max<br />

HIGH<br />

LOW<br />

COMMON<br />

1 2 3 4 5 6 7 8 9<br />

# 1 Button<br />

# 2 Button<br />

240 VAC<br />

2-Speed<br />

Pump<br />

120 VAC<br />

Aux.<br />

# 3 Button<br />

NOTE:<br />

The combined load on Terminals 6 & 7<br />

must NOT exceed 15 amps Resistive.<br />

120 VAC<br />

Aux.<br />

# 4 Button<br />

120 VAC<br />

Aux.<br />

# 5 Button<br />

Figure 3-15<br />

Copyright © 2010 Intermatic, Inc.