Fisher® FIELDVUE DVC6200 Digital Valve Controller
Fisher® FIELDVUE DVC6200 Digital Valve Controller
Fisher® FIELDVUE DVC6200 Digital Valve Controller
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Field Communicator Menu Trees<br />
July 2012<br />
Instruction Manual<br />
D103605X012<br />
Figure B-7. Manual Setup > Tuning (2-2-4) through Manual Setup > Outputs (2-2-7)<br />
Manual Setup<br />
1 Mode and Protection<br />
2 Instrument<br />
3 Travel/Pressure Control<br />
4 Tuning<br />
5 <strong>Valve</strong> and Actuator<br />
6 Partial Stroke Test (PST)<br />
7 Outputs<br />
WITH I/O PACKAGE<br />
2-2-6 (HD, AD, PD)<br />
2-2-7 (ODV)<br />
Outputs<br />
1 Output Terminal Config<br />
2 Switch Configuration<br />
3 Transmitter Output 2<br />
4 HART Var Assignments 3<br />
5 Burst Mode 4<br />
2-2-6-5 (HC, AD, PD)<br />
4<br />
2-2-7-5 (ODV)<br />
Burst Mode<br />
1 Burst Enable<br />
2 Burst Command<br />
2-2-6-4 (HC, AD, PD)<br />
2-2-7-4 (ODV)<br />
HART Var Assignments<br />
1 Primary Variable (PV)<br />
2 Secondary Variable (SV)<br />
3 Tertiary Variable (TV)<br />
4 Quaternary Variable (QV)<br />
1<br />
WITH I/O PACKAGE<br />
2-2-4<br />
WITHOUT I/O PACKAGE<br />
Tuning<br />
1 Travel Tuning<br />
2 Pressure Tuning<br />
3 Travel/Pressure Integral Settings<br />
Travel/Pressure Integral Settings<br />
1 Integral Dead Zone<br />
2 Integrator Limit<br />
2-2-6-1 (HC, AD, PD)<br />
2-2-7-1 (ODV)<br />
Output Terminal Config<br />
1 Output Terminal Enable<br />
2 Function<br />
3 Fail Signal<br />
2-2-6-2 (HC, AD, PD)<br />
2-2-7-2 (ODV)<br />
Switch Configuration<br />
1 Limit Switch Trip Point<br />
2 Alert Switch Source<br />
3 Switch Closed<br />
2-2-4-3<br />
2-2-5<br />
<strong>Valve</strong> and Actuator<br />
1 <strong>Valve</strong> Style<br />
2 Actuator Style<br />
3 Feedback Connection<br />
4 Relay Type<br />
5 Zero Power Condition<br />
6 Travel Sensor Motion<br />
7 Maximum Supply Pressure<br />
2-2-6<br />
Partial Stroke Test (PST) 1<br />
1 PST Pressure Limit<br />
2 PST Enable<br />
3 PST Start Point<br />
4 PST Variables<br />
WITHOUT I/O PACKAGE<br />
2-2-6 (HD, AD, PD)<br />
2-2-7 (ODV)<br />
Outputs<br />
1 HART Var Assignments<br />
2 Burst 4<br />
2-2-6-2 (HC, AD, PD)<br />
4<br />
2-2-7-2 (ODV)<br />
Burst Mode<br />
1 Burst Enable<br />
2 Burst Command<br />
2-2-4-1<br />
Travel Tuning<br />
1 Travel Tuning Set<br />
2 Proportional Gain<br />
3 Velocity Gain<br />
4 MLFB Gain<br />
5 Integral Enable<br />
6 Integral Gain<br />
7 Performance Tuner<br />
8 Stabilize/Optimize<br />
2-2-4-2<br />
Pressure Tuning<br />
1 Pressure Tuning Set<br />
2 Proportional Gain<br />
3 MLFB Gain<br />
4 Integral Enable<br />
5 Integral Gain<br />
2-2-6-1 (HC, AD, PD)<br />
2-2-7-1 (ODV)<br />
HART Var Assignments<br />
1 Primary Variable (PV)<br />
2 Secondary Variable (SV)<br />
3 Tertiary Variable (TV)<br />
4 Quaternary Variable (QV)<br />
5<br />
NOTES:<br />
1 PARTIAL STROKE TEST (PST) IS AVAILABLE FOR INSTRUMENT LEVEL ODV.<br />
2 THIS MENU ITEM IS HART VAR ASSIGNMENTS WITH HART 5.<br />
3 THIS MENU ITEM IS TRANSMITTER OUTPUT WITH HART 5.<br />
4 BURST MODE IS AVAILABLE WITH HART 5.<br />
5 PERFORMANCE TUNER IS AVAILABLE FOR INSTRUMENT LEVEL AD, PD, AND ODV.<br />
88