JT5 Operator’s <strong>Manual</strong> Systems and Equipment - 99<br />

Electric Strike System<br />

Problem Possible cause Possible solution<br />

Strobe light on drilling unit<br />

does not work during total<br />

test<br />

Improper connections with<br />

control module<br />

Check connections and wiring<br />

harness<br />

Defective strobe light 1. Disconnect strobe and connect to<br />

external 12V power source.<br />

2. If strobe does not work, replace it.<br />

Alarm on drilling unit does<br />

not work during total test<br />

Defective control module<br />

Improper connections with<br />

control module<br />

Have control module checked or<br />

replaced<br />

Check connections and wiring<br />

harness<br />

Defective alarm 1. Disconnect strobe and connect to<br />

external 12V power source.<br />

2. If strobe does not work, replace it.<br />

Strobe light and alarm on<br />

drilling unit do not work<br />

during total test<br />

Defective control module<br />

Improper connections with<br />

control module<br />

Defective control module<br />

Have control module checked or<br />

replaced<br />

Check connections and wiring<br />

harness<br />

Have control module checked or<br />

replaced<br />

EC2 code displays and<br />

current problem indicator is<br />

on<br />

Improper connections with<br />

control module<br />

Check cable connections on control<br />

module and current transformer<br />

Defective current transformer 1. Disconnect current transformer.<br />

2. Check for 20-40 ohms from pin 1<br />

to pin 4, 20-40 ohms from pin 1 to<br />

pin 2, and less than 1 ohm from<br />

pin 2 to pin 4.<br />

EV1 code displays and<br />

voltage problem indicator is<br />

on<br />

Defective current transformer<br />

cable<br />

Defective control module<br />

Improper connection of voltage<br />

limiter to ground stake<br />

Defective voltage limiter<br />

Defective control module<br />

1. Disconnect cable from<br />

transformer and control module.<br />

2. Check continuity of cable.<br />

3. If continuity is zero or cable is<br />

damaged, replace.<br />

Have control module checked or<br />

replaced<br />

Check voltage limiter connection to<br />

ground stake and verify that ground<br />

stake is driven into the ground<br />

Have voltage limiter checked or<br />

replaced<br />

Have control module checked or<br />

replaced<br />