JT5 Operator’s <strong>Manual</strong> Service - 143<br />

150 Hour<br />

150 Hour<br />

Change Engine Oil and Filter<br />

Change engine oil every 150 hours while oil is<br />

warm and with unit parked on level ground.<br />

1. Open drain (3).<br />

2. Drain crankcase while oil is warm.<br />

3. Replace filter (4).<br />

4. Close drain.<br />

5. Add DEO at fill (2) until oil level is at highest<br />

line on dipstick (1).<br />

250 Hour<br />

Change Hydraulic Fluid Filter<br />

Change filter (shown) every 250 hours. Change<br />

more often if indicated by filter indicator.<br />

500 Hour<br />

Replace Fan Belt<br />

Replace fan belt (shown) every 500 hours.<br />

To replace<br />

1. Loosen bolts (1, 2) and remove belt.<br />

2. Install new belt and adjust properly. See<br />

page 148.<br />