Safety - 18<br />

If an Electric Line is Damaged<br />

JT2720 Mach 1/All Terrain Operator’s <strong>Manual</strong><br />

Emergency Procedures<br />

If you suspect an electric line has been damaged and you are on drilling unit or bonded equipment, DO<br />

NOT MOVE. Remain on drilling machine or mats and take the following actions. The order and degree of<br />

action will depend on the situation.<br />

• Warn people nearby that an electric strike has occurred.<br />

• Have someone contact electric company.<br />

• Reverse drilling direction and try to break contact. Do not touch drill pipe with hands or hand-held<br />

tools.<br />

• Press electric strike system status button.<br />

• If alarm sounds again, stay where you are and wait for electric company to shut off power.<br />

• If alarm does not sound and there is no other indication of a strike, wait at least one full minute<br />

before moving away from equipment. Utility might use automatic reclosers which will restart<br />

current flow. If alarm sounds again while waiting, stay where you are until electric company shuts<br />

off power.<br />

• If alarm does not sound but all lights in strike indicator are on, assume strike is continuing and stay<br />

where you are until electric company shuts off power.<br />

• Do not resume drilling or allow anyone into area until given permission by electric company.<br />

If you suspect an electric line has been damaged and you are off drilling unit or bonded equipment, DO<br />

NOT TOUCH ANY EQUIPMENT connected to drilling unit. Take the following actions. The order and<br />

degree of action will depend on the situation.<br />

• Stay where you are unless you are wearing electric insulating boots. If you leave, do not return to area<br />

or allow anyone into area until given permission by electric company.<br />