Service - 142<br />

JT5 Operator’s <strong>Manual</strong><br />

100 Hour<br />

Check Fan Belt Tension<br />

Check pump drive belt tension every 100 hours.<br />

1. Turn off engine and remove key.<br />

2. Apply moderate thumb pressure to top of<br />

belt.<br />

Belt is properly tensioned when deflection (A)<br />

is 1/4-3/8” (7-9 mm). To adjust, see<br />

page 148.<br />