Systems and Equipment - 98<br />

Troubleshoot Strike System<br />

JT5 Operator’s <strong>Manual</strong><br />

Electric Strike System<br />

In addition to self-test diagnostic codes, other problem situations and their possible causes and solutions<br />

are listed in the chart below.<br />

Problem Possible cause Possible solution<br />

No lights or readings<br />

showing after drilling unit<br />

key has been on at least<br />

one minute<br />

Screen is blank<br />

Information on screen is<br />

visible during self test but<br />

not after test is complete<br />

OK indicator is on, but<br />

electrical power supply<br />

indicator is off<br />

Electrical power supply<br />

indicator is on, but OK<br />

indicator is off<br />

Problems in startup<br />

No power to strike system<br />

control module<br />

Defective control module<br />

Strike system is not getting<br />

adequate power from drilling<br />

unit<br />

Defective control module<br />

LCD contrast is not set properly<br />

Strike system is not getting<br />

adequate power from drilling<br />

unit<br />

Defective control module<br />

Problem detected during test<br />

Defective control module<br />

Push self test button. If problem goes<br />

away, retest strike system<br />

Check drilling unit electric system<br />

Check that harness from drilling unit<br />

to control module is connected<br />

Check that cable from drilling unit<br />

carries more than 10V<br />

Have control module checked or<br />

replaced<br />

Check drilling unit electric system<br />

Check that harness from drilling unit<br />

to control module is connected<br />

Check that harness from drilling unit<br />

carries more than 10V<br />

Have control module checked or<br />

replaced<br />

Contact your <strong>Ditch</strong> <strong>Witch</strong> dealer to<br />

adjust contrast<br />

Check drilling unit electric system<br />

Check that harness from drilling unit<br />

to control module is connected<br />

Check that harness from drilling unit<br />

carries more than 10V<br />

Have control module checked or<br />

replaced<br />

Check for error code and have control<br />

module checked or replaced<br />

Have control module checked or<br />

replaced<br />