JT5 Operator’s <strong>Manual</strong> Service - 149<br />

As Needed<br />

Replace Saver Sub<br />

Check saver sub and replace as needed. See your <strong>Ditch</strong> <strong>Witch</strong> dealer for replacement parts.<br />

To replace<br />

IMPORTANT: Saver sub must mate up to every drill pipe. Check sub for thread wear. If saver sub<br />

threads are more worn than pipe threads, saver sub is damaging the drill pipe.<br />

1. Remove six bolts from saver sub flange.<br />

2. Remove and discard saver sub.<br />

3. Replace o-ring, if necessary.<br />

4. Install new saver sub.<br />

5. Apply Loctite 242 to bolts and install. Tighten<br />

in a cross pattern to 28 ft•lb (38 N•m).<br />

Check Drilling Fluid Pump Check Valve<br />

Check fluid pump check valve (shown) o-ring for<br />

wear and replace as needed.<br />