Chapter 14 - Antennas Namespace<br />

antennas..advanced.computed_conducted_power<br />

This variable is the computed conducted power (in tenths of dB) on a port.<br />

The following example shows the advanced method for specifying the<br />

antenna data needed to have the reader set the conducted power for<br />

antenna number 1. The last command in the example reads the reader<br />

computed conducted power.<br />

NOTE: The computed conducted power is based on the region/sub_region<br />

and the value of 259 is only presented as an example. Your actual<br />

computed conducted power may be different based on the readers<br />

region/sub_region.<br />

>>> antennas.1.conducted_power = 0<br />

ok<br />

>>> antennas.1.advanced.gain_units = dBdC<br />

ok<br />

>>> antennas.1.advanced.gain = 50<br />

ok<br />

>>> antennas.1.advanced.cable_loss = 15<br />

ok<br />

>>> antennas.1.advanced.attenuation = 75<br />

ok<br />

>>> antennas.1.advanced.computed_conducted_power<br />

ok 259 = 1 to 4.<br />

Type<br />

var<br />

Permissions<br />

Data Type<br />

int<br />

Default 0<br />

Min<br />

Max<br />

Units<br />

ddB<br />

guest=r,admin=r<br />

154 <strong>INfinity</strong> <strong>510</strong> <strong>Protocol</strong> <strong>Reference</strong> <strong>Guide</strong>