Chapter 3 - Command Overview<br />

unauthenticated – When the default login level is set to unauthenticated, all<br />

clients that connect to the reader must login (with the reader.login()<br />

command) before they can access any features of the reader. Only the<br />

reader.login() command is accepted when the default login level is<br />

set to unauthenticated. This allows the reader to be locked down and forces<br />

all connecting clients to login before accessing the reader.<br />

guest – When the default login level is set to guest, all clients that connect<br />

to the reader are automatically logged in at the guest level at connection<br />

time. This means they can perform all guest permitted actions without<br />

issuing the reader.login() command.<br />

admin - When the default login level is set to admin, all clients that connect<br />

to the reader are automatically logged in at the admin level at connection<br />

time. This means they can perform all admin permitted actions without<br />

issuing the reader.login() command.<br />

The factory default login level is admin. This allows for a quick turn-up and<br />

initial testing of the reader. When the reader is deployed, set the default<br />

login level to the level that best suits your security/accessibility needs. To<br />

set the default login level, use the setup.default_login_level<br />

configuration variable. For example to set the default login level to guest<br />

use the following command:<br />

> setup.default_login_level = guest<br />

ok<br />

Embedded Application/Script Login<br />

You can customize your reader by writing applications and scripts that<br />

execute on the reader. When an application or script executes, it connect as<br />

a client. When an application or script running on the reader connects, it is<br />

automatically logged in at the admin level. This allows applications and<br />

scripts to run on any reader without knowing the password.<br />

12 <strong>INfinity</strong> <strong>510</strong> <strong>Protocol</strong> <strong>Reference</strong> <strong>Guide</strong>