Chapter 15 - Modem Namespace<br />

modem.diag.current_temperature<br />

This variable stores the last temperature value read from the RF board<br />

temperature sensor.<br />

Type<br />

Permissions<br />

Data Type<br />

var<br />

guest=r,admin=r<br />

int<br />

Default 0<br />

Min -20<br />

Max 100<br />

modem.diag.error_handler.period<br />

The longer this time, the less frequently you get events from the modem<br />

when there are multiple error/warning/info events of the same type.<br />

Type<br />

Permissions<br />

Data Type<br />

var<br />

guest=-,admin=rw<br />

int<br />

Default 60<br />

modem.protocol.cmd_retries<br />

This variable sets the number of command retries for a failed command.<br />

When a command sequence fails, it can be retried for the number of times<br />

indicated by this parameter. This is transparent to the user. Each protocol<br />

may also have a cmd_retries variable for retrying at the air interface<br />

command level.<br />

Type<br />

Permissions<br />

Data Type<br />

var<br />

guest=r,admin=rw<br />

int<br />

Default 3<br />

Min 0<br />

Max 8<br />