Chapter 11 - Com Namespace<br />

com.network.tcpkeepalive<br />

If this variable is set to true, communications with the reader will be<br />

performed with periodic keep alive transmissions to ensure any zombie<br />

connections are recognized and cleaned up. By default, this variable is<br />

true.<br />

The following example turns TCP Keep Alive off:<br />

>>> com.network.tcpkeepalive=false<br />

ok<br />

Type<br />

Permissions<br />

Data Type<br />

Default<br />

var<br />

guest=r,admin=rw<br />

bool<br />

true<br />

com.network.1.default_gateway<br />

This variable contains the default gateway used for the first network<br />

interface on the reader. Setting the default gateway to 0.0.0.0 will report a<br />

default gateway of none.<br />

The following example returns the default gateway of the first network<br />

interface on the reader. To set the default gateway, use the<br />

com.network.1.set() function.<br />

>>> com.network.1.default_gateway<br />

ok 10.1.1.1<br />

Type<br />

Permissions<br />

Data Type<br />

var<br />

Default ""<br />

guest=r,admin=r<br />

string<br />

90 <strong>INfinity</strong> <strong>510</strong> <strong>Protocol</strong> <strong>Reference</strong> <strong>Guide</strong>