Chapter 15 - Modem Namespace<br />

modem.protocol.isoc.physical.interrogator_mode<br />

This variable sets the reader mode for ISO-C. The reader can be in 1 of 3<br />

modes when ISO-C protocol is enabled: single interrogator, multiple<br />

interrogator, or dense interrogator. The selection depends on the<br />

environment and requirements.<br />

Type<br />

Permissions<br />

Data Type<br />

Default<br />

Enum<br />

var<br />

guest=r,admin=rw<br />

enum<br />

SINGLE<br />

SINGLE MULTI DENSE MAINT1 MAINT2<br />

modem.protocol.isoc.physical.modulation_depth<br />

This specifies the percent modulation depth for ISO-C transmissions. The<br />

ISO-C spec requires the depth to be between 80 % to 100%.<br />

Type<br />

var<br />

Permissions<br />

Data Type<br />

int<br />

Default 90<br />

Min 0<br />

Max 100<br />

guest=r,admin=rw<br />

modem.protocol.isoc.physical.pilot_tone<br />

This variable turns on the ISO-C pilot_tone from the tag. When true, the pilot<br />

tone is on and the tag will prepend 12 leading 0's to it's response preamble.<br />

Type<br />

Permissions<br />

Data Type<br />

Default<br />

var<br />

guest=r,admin=rw<br />

bool<br />

True<br />