Classical & Heritage lighting - Indal
Classical & Heritage lighting - Indal
Classical & Heritage lighting - Indal
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Standards & certifications<br />
STANDARDS<br />
<strong>Indal</strong> products comply with applicable standards, particularly:<br />
- EN 60598 for luminaires,<br />
- EN 40 for columns,<br />
- EN 62262 for impact resistance of enclosures (IK),<br />
- EN 60529 for degrees of protection of enclosures (IP),<br />
- EN 55015 and EN 61000 for electromagnetic compatibility.<br />
Standard EN 40 relating to columns<br />
All the compositions have been made in strict compliance with standard<br />
EN 40. For any requests for products that are not in the catalogue or for<br />
stronger wind zones, please contact our sales support department if we<br />
can design products to meet your personalised resistance requirements<br />
of your project.<br />
ELECTRICAL PROTECTIONS<br />
Class I<br />
Class II<br />
Functional insulation with the earthing of accessible<br />
metal parts<br />
Functional insulation supplemented by additional<br />
insulation or single reinforced insulation, no earthing<br />
PROTECTION OF ENCLOSURES (ip)<br />
European standard EN 40 applies to all public <strong>lighting</strong> columns made of<br />
steel, aluminium, composite or concrete as well as straight columns that do<br />
not exceed 20 meters, columns with brackets that do not exceed 18 meters<br />
and straight columns fitted with spotlights that are less than 15 meters<br />
high.<br />
Standard EN 40 defines the methodology of verification of a column by<br />
calculation or by mechanical testing. It also specifies the compliance<br />
tests that are to be carried out while manufacturing columns. It requires<br />
CE certification for columns.<br />
All public <strong>lighting</strong> columns made of steel and aluminium are calculated<br />
by our R&D department according to:<br />
- EN 40-3-1 Specification for characteristic loads,<br />
- EN 40-3-3 Verification by calculation.<br />
A verification by calculation takes into account all the fixing elements of<br />
columns such as anchor bolts, base plates, columns, bracket mounting,<br />
bracket or brackets, luminaire or luminaires and accessories.<br />
CE CERTIFICATION OF COLUMNS<br />
CE certification is mandatory. It authorises the release of products in the<br />
market. Certification is issued by organisations notified by the Member<br />
States of the European Union.<br />
A label with the CE mark is put on all columns, on the service door.<br />
The label also bears the name of the company, the number of the certifying<br />
organisation, the approval number of the company and the product code.<br />
With every invoice, you will be given a document with general information<br />
about the product and its agreed conventional value. That conventional<br />
value is calculated on the basis of the elements defined by the standard for<br />
the 24 m/s wind area, the terrain category 2 and the deformation class 3.<br />
1 st digit:<br />
ingress by solid bodies<br />
Not protected<br />
IP 0x<br />
Protected from solid bodies<br />
above 50mm<br />
IP 1x<br />
Protected from solid bodies<br />
above 12mm<br />
IP 2x<br />
Protected from solid bodies<br />
above 2.5mm<br />
IP 3x<br />
Protected from solid bodies<br />
above 1mm<br />
IP 4x<br />
Protected from dust<br />
IP 5x<br />
Dust tight<br />
IP 6x<br />
2 nd digit:<br />
water penetration<br />
Not protected<br />
IP x0<br />
Protected from vertically<br />
dripping water<br />
IP x1<br />
Protected from dripping water<br />
with a maximum angle of 15°<br />
IP x2<br />
Protected from dripping water<br />
with a maximum angle of 60°<br />
IP x3<br />
Protected from splashing water<br />
IP x4<br />
Protected from water jets<br />
IP x5<br />
Protected from heavy seas<br />
IP x6<br />
<strong>Classical</strong> & <strong>Heritage</strong> • page 282