22.01.2015 Views

this SIM5218 AT command manual - Cooking Hacks

this SIM5218 AT command manual - Cooking Hacks

this SIM5218 AT command manual - Cooking Hacks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SIM5218</strong> Serial <strong>AT</strong> Command Set<br />

OK<br />

Read Command<br />

<strong>AT</strong>+AUTOCSQ<br />

Write Command<br />

<strong>AT</strong>+AUTOCSQ=[,<<br />

mode>]<br />

Responses<br />

+AUTOCSQ: ,<br />

OK<br />

Responses<br />

OK<br />

ERROR<br />

Defined values<br />

<br />

0 – disable auto report<br />

1 – enable auto report<br />

<br />

0 – CSQ auto report every five seconds<br />

1 – CSQ auto report only after or changing<br />

NOTE If the parameter of is omitted when executing write <strong>command</strong>, will be set<br />

to default value.<br />

Examples<br />

<strong>AT</strong>+AUTOCSQ=<br />

+AUTOCSQ: (0-1),(0-1)<br />

OK<br />

<strong>AT</strong>+AUTOCSQ<br />

+AUTOCSQ: 1,1<br />

OK<br />

<strong>AT</strong>+AUTOCSQ=1,1<br />

OK<br />

+CSQ: 23,0 (when or changing)<br />

10.8 <strong>AT</strong>+CACM Accumulated call meter<br />

Description<br />

The <strong>command</strong> resets the Advice of Charge related accumulated call meter value in SIM file<br />

EFACM.<br />

SIM PIN References<br />

YES 3GPP TS 27.007<br />

Syntax<br />

Test Command<br />

Responses<br />

<strong>SIM5218</strong>_Serial _<strong>AT</strong>C_V1.36 211<br />

5/15/2012