SECTION 4<br />

<strong>PT</strong>-<strong>600</strong> Process Data<br />

150 Amperes<br />

Stainless Steel<br />

OPERATION<br />

Except where noted, data is for above water<br />

cutting. Reduce speed approximately 10% when<br />

cutting under water.<br />

Start<br />

Gas<br />

Cut<br />

Gas<br />

Shield<br />

Gas<br />

Material Thickness Air Air Air<br />

Timers<br />

IN 0.188 0.250 0.313 0.375 0.500 0.625 0.750 1.000<br />

MM 4,7 6,4 7,9 9,5 12,7 15,9 19,1 25,4<br />

Rise On Pierce (sec.) 0 0 0.1 0.1 0.2 0.3 0.4 0.4<br />

Pierce Delay (sec.) 0.1 0.3 0.3 0.3 0.4 0.4 0.8 1.0<br />

Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />

<strong>Plasma</strong> Start Gas<br />

<strong>Plasma</strong> Cut Gas<br />

Shield Start Gas<br />

Shield Cut Gas<br />

Height Readings<br />

Travel Speed<br />

Kerf Width<br />

Notes:<br />

Pilot Arc Set to High<br />

Initial Height<br />

PSI 25 25 25 25 25 25 25 25<br />

BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />

PSI 36 36 36 36 36 36 36 36<br />

BAR 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5<br />

PSI 20 20 20 20 20 20 20 20<br />

BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4<br />

PSI 22 22 22 22 22 22 22 22<br />

BAR 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5<br />

IN. .375 .375 .375 .375 .500 .625 .625 .625<br />

MM 9,5 9,5 9,5 9,5 12,7 15,9 15,9 15,9<br />

Arc Voltage (standoff) 145 147 152 155 162 169 177 189<br />

IPM 180 130 110 90 60 40 25 15<br />

MM/MIN 4572 3302 2794 2286 1524 1016 635 381<br />

Inches .100 .105 .115 .120 .125 .130 .140 .145<br />

Millimeters 2,5 2,6 2,9 3,0 3,2 3,3 3,6 3,7<br />

4-75