PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
150 Amperes<br />
Stainless Steel<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness Air Air Air<br />
Timers<br />
IN 0.188 0.250 0.313 0.375 0.500 0.625 0.750 1.000<br />
MM 4,7 6,4 7,9 9,5 12,7 15,9 19,1 25,4<br />
Rise On Pierce (sec.) 0 0 0.1 0.1 0.2 0.3 0.4 0.4<br />
Pierce Delay (sec.) 0.1 0.3 0.3 0.3 0.4 0.4 0.8 1.0<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 36 36 36 36 36 36 36 36<br />
BAR 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5<br />
PSI 20 20 20 20 20 20 20 20<br />
BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4<br />
PSI 22 22 22 22 22 22 22 22<br />
BAR 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5<br />
IN. .375 .375 .375 .375 .500 .625 .625 .625<br />
MM 9,5 9,5 9,5 9,5 12,7 15,9 15,9 15,9<br />
Arc Voltage (standoff) 145 147 152 155 162 169 177 189<br />
IPM 180 130 110 90 60 40 25 15<br />
MM/MIN 4572 3302 2794 2286 1524 1016 635 381<br />
Inches .100 .105 .115 .120 .125 .130 .140 .145<br />
Millimeters 2,5 2,6 2,9 3,0 3,2 3,3 3,6 3,7<br />
4-75