SECTION 4<br />

OPERATION<br />

LOW CURRENT CUTTING WITH AIR (50 to 100 Amps)<br />

1. Ensure that the correct components are assembled in the <strong>PT</strong>-<strong>600</strong> for the cutting conditions.<br />

2. To cut with air, disconnect N 2<br />

supply from the Flow Control. Connect a supply of clean, filtered air (approximately 100<br />

psig to the N 2<br />

inlet on the Flow Control.<br />

3. For low current cutting with the <strong>PT</strong>-<strong>600</strong> and ESP-1000 a cut gas regulator system is required for air. See figure 4-1 for<br />

assembly details.<br />

ADA<strong>PT</strong>OR<br />

999304<br />

1/4 N<strong>PT</strong>M*<br />

CHECK VALVE<br />

ASSEMBLY - 21124<br />

HEX. NIPPLE<br />

639501<br />

AIR REGULATOR<br />

ASSEMBLY -522368<br />

B-OXY -F*<br />

1/4 N<strong>PT</strong>M*<br />

CONNECTOR<br />

3389<br />

1/4 N<strong>PT</strong>F*<br />

* Use Locktite pipe sealant on threads, DO NOT use<br />

Teflon tape.<br />

(2) 1/8" N<strong>PT</strong><br />

PIPE PLUGS<br />

643792<br />

Figure 4-1. <strong>PT</strong>-<strong>600</strong> Regulator Assembly<br />

1/4 N<strong>PT</strong>F*<br />

1/4 N<strong>PT</strong>M*<br />

B-OXY-M*<br />

4. Set the O 2<br />

/N 2<br />

switch to N 2<br />

position.<br />

5. Place CUT WATER switch to OFF.<br />

6. Set CUT GAS Flow Rate.<br />

7. Position TEST/RUN switch to RUN 1.<br />

8. Set start gas pressure as follows:<br />

A. TEST/RUN switch to START GAS TEST.<br />

B. Adjust start gas regulator to 30 psig.<br />

C. Return TEST/RUN switch to RUN 1.<br />

9. Set cut gas pressure as follows:<br />

A. TEST/RUN switch to CUT GAS TEST<br />

B. Adjust cut gas regulator to 60 psig.<br />

C. Return TEST/RUN switch to RUN 1 position.<br />