PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
100 Amperes<br />
Aluminum<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness Air Air Air<br />
Timers<br />
IN 0.188 0.250 0.375 0.500 0.750<br />
MM 4,7 6,4 9,5 12,7 19,1<br />
Rise On Pierce (sec.) 0 0.1 0.1 0.1 0.2<br />
Pierce Delay (sec.) 0.1 0.2 0.3 0.3 0.4<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to Low<br />
Initial Height<br />
PSI 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7<br />
PSI 42 42 42 42 42<br />
BAR 2,9 2,9 2,9 2,9 2,9<br />
PSI 20 20 20 20 20<br />
BAR 1,4 1,4 1,4 1,4 1,4<br />
PSI 18 18 18 18 18<br />
BAR 1,24 1,24 1,24 1,24 1,24<br />
IN. .375 .375 .375 .500 .500<br />
MM 9,5 9,5 9,5 12,7 12,7<br />
Arc Voltage (standoff) 151 157 157 182 185<br />
IPM 120 95 70 50 25<br />
MM/MIN 3048 2413 1778 1270 635<br />
Inches .115 .120 .130 .130 .135<br />
Millimeters 2,9 3,0 3,3 3,3 3,5<br />
4-37