27.02.2015 Views

PT-600 Mechanized Plasma Cutting Torch

PT-600 Mechanized Plasma Cutting Torch

PT-600 Mechanized Plasma Cutting Torch

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SECTION 4<br />

<strong>PT</strong>-<strong>600</strong> Process Data<br />

200 Amperes<br />

Stainless Steel<br />

OPERATION<br />

Except where noted, data is for above water<br />

cutting. Reduce speed approximately 10% when<br />

cutting under water.<br />

Start<br />

Gas<br />

Cut<br />

Gas<br />

Shield<br />

Gas<br />

Material Thickness Air Air Air<br />

Timers<br />

IN 0.188 0.250 0.313 0.375 0.500 0.625 0.750 1.000<br />

MM 4,7 6,4 7,9 9,5 12,7 15,9 19,1 25,4<br />

Rise On Pierce (sec.) 0 0.1 0.1 0.1 0.1 0.2 0.3 0.4<br />

Pierce Delay (sec.) 0.2 0.2 0.3 0.3 0.4 0.5 0.8 1.0<br />

Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />

<strong>Plasma</strong> Start Gas<br />

<strong>Plasma</strong> Cut Gas<br />

Shield Start Gas<br />

Shield Cut Gas<br />

Height Readings<br />

Travel Speed<br />

Kerf Width<br />

Notes:<br />

Pilot Arc Set to High<br />

Initial Height<br />

PSI 25 25 25 25 25 25 25 28<br />

BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />

PSI 38 38 38 38 38 38 38 38<br />

BAR 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6<br />

PSI 20 20 20 20 20 20 20 20<br />

BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4<br />

PSI 22 22 22 22 22 22 22 22<br />

BAR 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5<br />

IN. .375 .375 .375 .375 .500 .625 .625 .750<br />

MM 9,5 9,5 9,5 9,5 12,7 15,9 15,9 19,1<br />

Arc Voltage (standoff) 148 150 154 159 159 165 170 183<br />

IPM 200 135 130 125 85 70 55 20<br />

MM/MIN 5080 3429 3302 3175 2159 1778 1397 508<br />

Inches .105 .110 .105 .130 .125 .130 .135 .175<br />

Millimeters 2,6 2,8 2,6 3,3 3,1 3,3 3,5 4,5<br />

4-77