<strong>PT</strong>-<strong>600</strong> Process Data<br />
200 Amperes<br />
Stainless Steel<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness Air Air Air<br />
Timers<br />
IN 0.188 0.250 0.313 0.375 0.500 0.625 0.750 1.000<br />
MM 4,7 6,4 7,9 9,5 12,7 15,9 19,1 25,4<br />
Rise On Pierce (sec.) 0 0.1 0.1 0.1 0.1 0.2 0.3 0.4<br />
Pierce Delay (sec.) 0.2 0.2 0.3 0.3 0.4 0.5 0.8 1.0<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25 25 28<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 38 38 38 38 38 38 38 38<br />
BAR 2,6 2,6 2,6 2,6 2,6 2,6 2,6 2,6<br />
PSI 20 20 20 20 20 20 20 20<br />
BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,4<br />
PSI 22 22 22 22 22 22 22 22<br />
BAR 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5<br />
IN. .375 .375 .375 .375 .500 .625 .625 .750<br />
MM 9,5 9,5 9,5 9,5 12,7 15,9 15,9 19,1<br />
Arc Voltage (standoff) 148 150 154 159 159 165 170 183<br />
IPM 200 135 130 125 85 70 55 20<br />
MM/MIN 5080 3429 3302 3175 2159 1778 1397 508<br />
Inches .105 .110 .105 .130 .125 .130 .135 .175<br />
Millimeters 2,6 2,8 2,6 3,3 3,1 3,3 3,5 4,5<br />