PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
150 Amperes<br />
Aluminum<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness Air Air Air<br />
Timers<br />
IN 0.188 0.250 0.313 0.375 0.500 0.750 0.875 1.000<br />
MM 4,7 6,4 7,9 9,5 12,7 19,1 22,2 25,4<br />
Rise On Pierce (sec.) 0 0 0 0 0.1 0.2 0.4 0.4<br />
Pierce Delay (sec.) 0 0.1 0.2 0.2 0.3 0.5 0.6 0.7<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 40 40 40 40 40 40 40 40<br />
BAR 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8<br />
PSI 15 15 15 10 15 10 10 10<br />
BAR 1,0 1,0 1,0 0,7 1,0 0,7 0,7 0,7<br />
PSI 15 15 15 10 15 10 10 10<br />
BAR 1,0 1,0 1,0 0,7 1,0 0,7 0,7 0,7<br />
IN. .375 .375 .375 .375 .500 .500 .500 .500<br />
MM 9,5 9,5 9,5 9,5 12,7 12,7 12,7 12,7<br />
Arc Voltage (standoff) 147 152 153 159 165 175 184 187<br />
IPM 200 140 120 100 80 45 37 30<br />
MM/MIN 5080 3556 3048 2540 2032 1143 940 762<br />
Inches .110 .110 .120 .130 .140 .140 .150 .150<br />
Millimeters 2,8 2,8 3,0 3,3 3,6 3,6 3,8 3,8<br />
4-39