SECTION 4<br />

<strong>PT</strong>-<strong>600</strong> Process Data<br />

150 Amperes<br />

Aluminum<br />

OPERATION<br />

Except where noted, data is for above water<br />

cutting. Reduce speed approximately 10% when<br />

cutting under water.<br />

Start<br />

Gas<br />

Cut<br />

Gas<br />

Shield<br />

Gas<br />

Material Thickness Air Air Air<br />

Timers<br />

IN 0.188 0.250 0.313 0.375 0.500 0.750 0.875 1.000<br />

MM 4,7 6,4 7,9 9,5 12,7 19,1 22,2 25,4<br />

Rise On Pierce (sec.) 0 0 0 0 0.1 0.2 0.4 0.4<br />

Pierce Delay (sec.) 0 0.1 0.2 0.2 0.3 0.5 0.6 0.7<br />

Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />

<strong>Plasma</strong> Start Gas<br />

<strong>Plasma</strong> Cut Gas<br />

Shield Start Gas<br />

Shield Cut Gas<br />

Height Readings<br />

Travel Speed<br />

Kerf Width<br />

Notes:<br />

Pilot Arc Set to High<br />

Initial Height<br />

PSI 25 25 25 25 25 25 25 25<br />

BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />

PSI 40 40 40 40 40 40 40 40<br />

BAR 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8<br />

PSI 15 15 15 10 15 10 10 10<br />

BAR 1,0 1,0 1,0 0,7 1,0 0,7 0,7 0,7<br />

PSI 15 15 15 10 15 10 10 10<br />

BAR 1,0 1,0 1,0 0,7 1,0 0,7 0,7 0,7<br />

IN. .375 .375 .375 .375 .500 .500 .500 .500<br />

MM 9,5 9,5 9,5 9,5 12,7 12,7 12,7 12,7<br />

Arc Voltage (standoff) 147 152 153 159 165 175 184 187<br />

IPM 200 140 120 100 80 45 37 30<br />

MM/MIN 5080 3556 3048 2540 2032 1143 940 762<br />

Inches .110 .110 .120 .130 .140 .140 .150 .150<br />

Millimeters 2,8 2,8 3,0 3,3 3,6 3,6 3,8 3,8<br />

4-39