SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
UNDER WATER<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
400 Amperes<br />
Carbon Steel<br />
Shield<br />
Gas<br />
Material Thickness N 2<br />
O 2<br />
Air<br />
Timers<br />
IN 0.500 0.625 0.750 1.000 1.250 1.500<br />
MM 12,7 15,9 19,1 25,4 31,8 38,1<br />
Rise On Pierce (sec.) 0.3 0.3 0.3 0.5 0.5 0.7<br />
Pierce Delay (sec.) 0.2 0.3 0.3 0.3 0.7 1.2<br />
OPERATION<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 31 31 31 31 31 31<br />
BAR 2,7 2,6 2,6 2,6 2,6 2,5<br />
PSI 22 22 22 22 22 22<br />
BAR 1,5 1,5 1,5 1,5 1,5 1,5<br />
PSI 22 22 22 22 22 22<br />
BAR 1,5 1,5 1,5 1,5 1,5 1,5<br />
IN. .500 .500 .500 .625 .625 .625<br />
MM 12,7 12,7 12,7 15,9 15,9 15,9<br />
Arc Voltage (standoff) 125 132 136 141 142 150<br />
IPM 130 120 110 75 55 37<br />
MM/MIN 3556 3175 2794 1905 1397 940<br />
Inches .145 .150 .195 .195 .205 .220<br />
Millimeters 3,7 3,8 5,0 5,0 5,2 5,6<br />
4-31