SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
360 Amperes<br />
Aluminum<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness N 2<br />
N 2<br />
Air<br />
Timers<br />
IN 0.250 0.375 0.500 0.750 1.000 1.250<br />
MM 6,4 9,5 12,7 19,1 25,4 31,8<br />
Rise On Pierce (sec.) 0 0 0 0.2 0.3 0.3<br />
Pierce Delay (sec.) 0.1 0.2 0.3 0.4 0.7 0.8<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 39 39 39 39 39 39<br />
BAR 2,7 2,7 2,7 2,7 2,7 2,7<br />
PSI 44 44 44 44 44 44<br />
BAR 3,0 3,0 3,0 3,0 3,0 3,0<br />
PSI 44 44 44 44 44 44<br />
BAR 3,0 3,0 3,0 3,0 3,0 3,0<br />
IN. .375 .375 .500 .500 .500 .500<br />
MM 9,5 9,5 12,7 12,7 12,7 12,7<br />
Arc Voltage (standoff) 147 155 161 168 168 190<br />
IPM 230 180 160 90 60 40<br />
MM/MIN 5842 4572 4064 2286 1524 1016<br />
Inches .120 .130 .130 .140 .150 .200<br />
Millimeters 3,0 3,3 3,3 3,6 3,8 5,1<br />