SECTION 4<br />

<strong>PT</strong>-<strong>600</strong> Process Data<br />

360 Amperes<br />

Aluminum<br />

OPERATION<br />

Except where noted, data is for above water<br />

cutting. Reduce speed approximately 10% when<br />

cutting under water.<br />

Start<br />

Gas<br />

Cut<br />

Gas<br />

Shield<br />

Gas<br />

Material Thickness N 2<br />

N 2<br />

Air<br />

Timers<br />

IN 0.250 0.375 0.500 0.750 1.000 1.250<br />

MM 6,4 9,5 12,7 19,1 25,4 31,8<br />

Rise On Pierce (sec.) 0 0 0 0.2 0.3 0.3<br />

Pierce Delay (sec.) 0.1 0.2 0.3 0.4 0.7 0.8<br />

Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />

<strong>Plasma</strong> Start Gas<br />

<strong>Plasma</strong> Cut Gas<br />

Shield Start Gas<br />

Shield Cut Gas<br />

Height Readings<br />

Travel Speed<br />

Kerf Width<br />

Notes:<br />

Pilot Arc Set to High<br />

Initial Height<br />

PSI 25 25 25 25 25 25<br />

BAR 1,7 1,7 1,7 1,7 1,7 1,7<br />

PSI 39 39 39 39 39 39<br />

BAR 2,7 2,7 2,7 2,7 2,7 2,7<br />

PSI 44 44 44 44 44 44<br />

BAR 3,0 3,0 3,0 3,0 3,0 3,0<br />

PSI 44 44 44 44 44 44<br />

BAR 3,0 3,0 3,0 3,0 3,0 3,0<br />

IN. .375 .375 .500 .500 .500 .500<br />

MM 9,5 9,5 12,7 12,7 12,7 12,7<br />

Arc Voltage (standoff) 147 155 161 168 168 190<br />

IPM 230 180 160 90 60 40<br />

MM/MIN 5842 4572 4064 2286 1524 1016<br />

Inches .120 .130 .130 .140 .150 .200<br />

Millimeters 3,0 3,3 3,3 3,6 3,8 5,1<br />

4-61