PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
260 Amperes<br />
Stainless Steel<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness N2 N2 Air<br />
Timers<br />
IN 0.250 0.375 0.500 0.625 0.750 1.000 1.250<br />
MM 6,4 9,5 12,7 15,9 19,1 25,4 31,8<br />
Rise On Pierce (sec.) 0 0.2 0.2 0.3 0.3 0.4 0.7<br />
Pierce Delay (sec.) 0.2 0.3 0.5 0.6 0.6 0.9 1.3<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 46 46 46 46 46 46 46<br />
BAR 3,2 3,2 3,2 3,2 3,2 3,2 3,2<br />
PSI 20 20 20 20 20 20 20<br />
BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4<br />
PSI 18 18 18 18 18 18 18<br />
BAR 1,2 1,2 1,2 1,2 1,2 1,2 1,2<br />
IN. .375 .375 .500 .625 .625 .750 .750<br />
MM 9,5 9,5 12,7 15,9 15,9 19,1 19,1<br />
Arc Voltage (standoff) 136 142 157 160 168 180 190<br />
IPM 170 135 110 70 50 30 15<br />
MM/MIN 4318 3429 2794 1778 1270 762 381<br />
Inches .110 .110 .115 .120 .130 .140 .160<br />
Millimeters 2,8 2,8 2,9 3,0 3,3 3,6 4,1<br />
4-85