SECTION 4<br />

<strong>PT</strong>-<strong>600</strong> Process Data<br />

260 Amperes<br />

Stainless Steel<br />

OPERATION<br />

Except where noted, data is for above water<br />

cutting. Reduce speed approximately 10% when<br />

cutting under water.<br />

Start<br />

Gas<br />

Cut<br />

Gas<br />

Shield<br />

Gas<br />

Material Thickness N2 N2 Air<br />

Timers<br />

IN 0.250 0.375 0.500 0.625 0.750 1.000 1.250<br />

MM 6,4 9,5 12,7 15,9 19,1 25,4 31,8<br />

Rise On Pierce (sec.) 0 0.2 0.2 0.3 0.3 0.4 0.7<br />

Pierce Delay (sec.) 0.2 0.3 0.5 0.6 0.6 0.9 1.3<br />

Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />

<strong>Plasma</strong> Start Gas<br />

<strong>Plasma</strong> Cut Gas<br />

Shield Start Gas<br />

Shield Cut Gas<br />

Height Readings<br />

Travel Speed<br />

Kerf Width<br />

Notes:<br />

Pilot Arc Set to High<br />

Initial Height<br />

PSI 25 25 25 25 25 25 25<br />

BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />

PSI 46 46 46 46 46 46 46<br />

BAR 3,2 3,2 3,2 3,2 3,2 3,2 3,2<br />

PSI 20 20 20 20 20 20 20<br />

BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4<br />

PSI 18 18 18 18 18 18 18<br />

BAR 1,2 1,2 1,2 1,2 1,2 1,2 1,2<br />

IN. .375 .375 .500 .625 .625 .750 .750<br />

MM 9,5 9,5 12,7 15,9 15,9 19,1 19,1<br />

Arc Voltage (standoff) 136 142 157 160 168 180 190<br />

IPM 170 135 110 70 50 30 15<br />

MM/MIN 4318 3429 2794 1778 1270 762 381<br />

Inches .110 .110 .115 .120 .130 .140 .160<br />

Millimeters 2,8 2,8 2,9 3,0 3,3 3,6 4,1<br />

4-85