<strong>PT</strong>-<strong>600</strong> Process Data<br />
100 Amperes<br />
Carbon Steel<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness N 2<br />
O 2<br />
Air<br />
Timers<br />
IN 0.125 0.188 0.250 0.313 0.375 0.500 0.625 0.750<br />
MM 3,2 4,7 6,4 7,9 9,5 12,7 15,9 19,1<br />
Rise On Pierce (sec.) 0 0 0 0 0.2 0.4 0.5 0.3<br />
Pierce Delay (sec.) 0 0 0 0 0.2 0.5 0.6 0.7<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
PSI 25 25 25 25 25 25 25 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />
PSI 46 46 44 46 46 46 48 46<br />
BAR 3,2 3,2 3,0 3,2 3,2 3,2 3,3 3,2<br />
PSI 20 20 20 20 20 20 20 18<br />
BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,2<br />
PSI 10 18 18 10 16 10 12 10<br />
BAR 0,7 1,2 1,2 0,7 1,1 0,7 0,8 0,7<br />
IN. .375 .375 .375 .375 .375 .500 .500 .500<br />
Initial Height<br />
MM 9,5 9,5 9,5 9,5 9,5 12,7 12,7 12,7<br />
Arc Voltage (standoff) 123 135 133 134 149 141 159 162<br />
IPM 190 150 120 100 80 60 38 20<br />
MM/MIN 4826 3810 3048 2540 2032 1524 965 508<br />
Inches .08 .075 .100 .085 .012 .100 .14 .145<br />
Notes:<br />
Pilot Arc Set to Low<br />
Millimeters 2,0 1,9 2,5 2,2 3,0 2,5 3,6 3,7<br />