SECTION 4<br />

<strong>PT</strong>-<strong>600</strong> Process Data<br />

100 Amperes<br />

Carbon Steel<br />

OPERATION<br />

Except where noted, data is for above water<br />

cutting. Reduce speed approximately 10% when<br />

cutting under water.<br />

Start<br />

Gas<br />

Cut<br />

Gas<br />

Shield<br />

Gas<br />

Material Thickness N 2<br />

O 2<br />

Air<br />

Timers<br />

IN 0.125 0.188 0.250 0.313 0.375 0.500 0.625 0.750<br />

MM 3,2 4,7 6,4 7,9 9,5 12,7 15,9 19,1<br />

Rise On Pierce (sec.) 0 0 0 0 0.2 0.4 0.5 0.3<br />

Pierce Delay (sec.) 0 0 0 0 0.2 0.5 0.6 0.7<br />

Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />

Height Readings<br />

Travel Speed<br />

Kerf Width<br />

<strong>Plasma</strong> Start Gas<br />

<strong>Plasma</strong> Cut Gas<br />

Shield Start Gas<br />

Shield Cut Gas<br />

PSI 25 25 25 25 25 25 25 25<br />

BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7<br />

PSI 46 46 44 46 46 46 48 46<br />

BAR 3,2 3,2 3,0 3,2 3,2 3,2 3,3 3,2<br />

PSI 20 20 20 20 20 20 20 18<br />

BAR 1,4 1,4 1,4 1,4 1,4 1,4 1,4 1,2<br />

PSI 10 18 18 10 16 10 12 10<br />

BAR 0,7 1,2 1,2 0,7 1,1 0,7 0,8 0,7<br />

IN. .375 .375 .375 .375 .375 .500 .500 .500<br />

Initial Height<br />

MM 9,5 9,5 9,5 9,5 9,5 12,7 12,7 12,7<br />

Arc Voltage (standoff) 123 135 133 134 149 141 159 162<br />

IPM 190 150 120 100 80 60 38 20<br />

MM/MIN 4826 3810 3048 2540 2032 1524 965 508<br />

Inches .08 .075 .100 .085 .012 .100 .14 .145<br />

Notes:<br />

Pilot Arc Set to Low<br />

Millimeters 2,0 1,9 2,5 2,2 3,0 2,5 3,6 3,7<br />