27.02.2015 Views

PT-600 Mechanized Plasma Cutting Torch

PT-600 Mechanized Plasma Cutting Torch

PT-600 Mechanized Plasma Cutting Torch

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SECTION 2<br />

DESCRI<strong>PT</strong>ION<br />

2.4 <strong>PT</strong>-<strong>600</strong> Technical Specifications<br />

2.4.1 <strong>Plasma</strong> Gas Technical Specifications<br />

Type O 2<br />

, N 2<br />

, Air, H-35<br />

Pressure<br />

100 to 125 psig (6,9 – 8,6 bars)<br />

250 cfh (118 l/min) max. at <strong>600</strong>A<br />

Flow<br />

(varies with application)<br />

O 2<br />

-99.5%<br />

N<br />

Purity Required*<br />

2<br />

-99.995%<br />

H-35 Specialty gas<br />

Air-clean, dry and oil free<br />

Recommended Liquid Cylinder Service Oxygen: R-76-150-540LC (P/N 19777)<br />

Regulators<br />

Inert gas: R-76-150-580LC (P/N 19977)<br />

Oxygen: R-77-150-540 (P/N 998337<br />

Hydrogen/Methane:R-77-150-350 (P/N<br />

Recommended Cylinder 2-Stage 998342)<br />

Regulators<br />

Nitrogen: R-77-150-580 (P/N 998344)<br />

Industrial Air: R-77150-590 (P/N<br />

998348)<br />

Recommended Heavy –Duty Hi-flow<br />

Oxygen: R-76-150-024 (P/N 19151)<br />

Station or Pipeline Regulators<br />

Recommended High-capacity Station<br />

R-6703 (P/N 22236)<br />

or Pipeline Regulators<br />

Gas Filter Required 25 micron w/bowl guard (P/N 56998133)<br />

2.4.2 Start Gas Technical Specifications<br />

Type N 2<br />

, Air, H-35<br />

Pressure<br />

100 to 125 psig (6,9 – 8,6 bars)<br />

Flow<br />

250 cfh (118 l/min) max @ <strong>600</strong>A<br />

(varies with application)<br />

Minimum Purity Required 99.995% clean, dry, oil free<br />

2.4.3 Secondary Gas Technical Specifications<br />

Type<br />

2-2<br />

N 2<br />

, Air<br />

Pressure<br />

100 to 125 psig (6.9 – 8,6 bars)<br />

Flow<br />

485 cfh (228,9 l/min) max (varies with<br />

application)<br />

Minimum Purity Required<br />

99.995% clean, dry, oil free (Same source as<br />

start gas)<br />

Gas Filter Required 25 micron w/bowl guard (P/N 56998133)<br />

2.4.4 <strong>PT</strong>-<strong>600</strong> <strong>Torch</strong> Technical Specifications<br />

Type<br />

Rating<br />

Dimensions<br />

Water-Cooled, Dual Gas<br />

<strong>600</strong> amps @ 100 % duty cycle<br />

See Package Options (2.3). This section.