PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
PT-600 Mechanized Plasma Cutting Torch
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SECTION 4<br />
<strong>PT</strong>-<strong>600</strong> Process Data<br />
250 Amperes<br />
Carbon Steel<br />
OPERATION<br />
Except where noted, data is for above water<br />
cutting. Reduce speed approximately 10% when<br />
cutting under water.<br />
Start<br />
Gas<br />
Cut<br />
Gas<br />
Shield<br />
Gas<br />
Material Thickness N 2<br />
O 2<br />
Air<br />
Timers<br />
IN 0.250 0.375 0.500 0.625 0.750 1.000 1.250 1.500<br />
MM 6,4 9,5` 12,7 15,9 19,1 25,4 31,8 38,1<br />
Rise On Pierce (sec.) 0 0 0 0.2 0.3 0.3 0.5 0.8<br />
Pierce Delay (sec.) 0 0 0.2 0.1 0.2 0.4 0.8 1.2<br />
Setup Parameters Pounds per Square Inch (PSI - Pressure)<br />
<strong>Plasma</strong> Start Gas<br />
<strong>Plasma</strong> Cut Gas<br />
Shield Start Gas<br />
Shield Cut Gas<br />
Height Readings<br />
Travel Speed<br />
Kerf Width<br />
Notes:<br />
Pilot Arc Set to High<br />
Initial Height<br />
PSI 25 25 25 25 25 25 26 25<br />
BAR 1,7 1,7 1,7 1,7 1,7 1,7 1,8 1,7<br />
PSI 38 38 44 40 38 38 43 44<br />
BAR 2,6 2,6 3,0 2,8 2,6 2,6 3,0 3,0<br />
PSI 18 18 20 14 18 18 22 22<br />
BAR 1,2 1,2 1,4 1,0 1,2 1,2 1,5 1,5<br />
PSI 12 12 16 12 12 12 22 22<br />
BAR 0,8 0,8 1,1 0,8 0,8 0,8 1,5 1,5<br />
IN. .375 .375 .500 .500 .500 .625 .625 .625<br />
MM 9,5 9,5 12,7 12,7 12,7 15,9 15,9 15,9<br />
Arc Voltage (standoff) 130 135 135 138 142 150 162 168<br />
IPM 170 125 115 80 65 50 33 22<br />
MM/MIN 4318 3175 2921 2032 1651 1270 838 558<br />
Inches .110 .135 .135 .130 .150 .160 .170 .200<br />
Millimeters 2,8 3,5 3,5 3,3 3,8 4,1 4,3 5,1<br />
4-25